Any displayed trace for channel 2 is magnified to match the voltage setting. When the cursor is positioned over the slider, the present setting pops up as a tooltip. If this box is unchecked, the rest of the channel 2 controls below disappear, because they are no longer relevant.Ĭhannel 2 Volts/Div: This slider controls the input sensitivity for channel 2. Channel 2 ControlsĬontrols associated with channel 2 are generally cyan in color.Ĭhannel 2 Enable: When checked, this box enables channel 2 for display. As this slider is moved, a faint line appears on the Display Window to graphically indicate the trigger level. When the cursor is positioned over this control, a tooltip pops up indicating the present voltage level for the trigger. Note: Channel 1 and Channel 2 cannot be simultaneously selected as the trigger source, however, it is possible to deselect both, resulting in a free-running trace based on no trigger condition at all.Ĭhannel 1 Trigger Slope: This selects the slope of the trigger – rising edge, falling edge, or both edges.Ĭhannel 1 Trigger Level: This slider sets the trigger level for channel 1. When unchecked, the channel 1 Trigger Slope and Trigger Level controls below disappear, as they are no longer relevant. As this slider is moved, a faint line appears on the Display Window to graphically indicate the zero level for the channel 1.Ĭhannel 1 as Trigger Source: When checked, channel 1 is selected as the trigger source. If the scope is running, the next trace is captured at the selected voltage setting.Ĭhannel 1 Probe Attenuation: This must be set to match the probe attenuation on channel 1.Ĭhannel 1 Position: This slider controls the vertical position of the trace for channel 1. Any displayed trace for channel 1 is magnified to match the voltage setting. If this box is unchecked, the rest of the channel 1 controls below disappear, as they are no longer relevant.Ĭhannel 1 Volts/Div: This slider controls the input sensitivity for channel 1. Items associated with channel 1 are generally yellow.Ĭhannel 1 Enable: When checked, this box enables channel 1 for display. If the scope is running, the next trace is captured at the selected time setting. Any displayed trace is magnified to match the time setting. When the cursor is positioned over this slider, the present setting pops up as a tooltip. Time/Div (Sweep) Slider: This is like the sweep rate knob on a classic oscilloscope. Click on parts of the picture to jump to an explanation of the items. But once you understand the basic layout of the program, everything should be simple. BasicScope can seem daunting initially because of the lack of familiar knobs and labels.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |